Miniature · Force and press testing, Filling and dosing

MI-50

Compact column cell for robotics, test fixtures and inline force measurement where space is the constraint.

Capacities: 50 g / 100 g / 200 g / 500 g / 1 kg / 2 kg / 5 kgC61.0 mV/VCombined error ≤ 0.005 %F.SCreep ≤ 0.008 %F.SIP65Safe overload 150 % F.S

Full specification

Every figure below is measured under controlled laboratory conditions. Test conditions are stated with the data. A per-unit calibration certificate is supplied with every sample and production order.

Capacity and accuracy

Rated capacity
50 g / 100 g / 200 g / 500 g / 1 kg / 2 kg / 5 kg
Sensitivity (rated output)
1.0 mV/V
Accuracy class
C6
Combined error
≤ 0.005 %F.S
Non-linearity
≤ 0.005 %F.S
Hysteresis
≤ 0.005 %F.S
Repeatability
≤ 0.005 %F.S
Creep (30 min)
≤ 0.008 %F.S
Zero balance
± 0.05 mV/V
Safe overload
150 % F.S
Ultimate overload
300 % F.S

Temperature

Temperature effect on zero
0.02 %F.S / 10 °C
Temperature effect on output
0.02 %F.S / 10 °C
Compensated temperature range
−10 to +40 °C
Operating temperature range
−30 to +80 °C

Electrical

Recommended excitation
5 VDC
Maximum excitation
10 VDC
Input impedance
405 ± 5 Ω
Output impedance
350 ± 3 Ω
Insulation resistance
≥ 5000 MΩ @ 100 VDC
Recommended cable
4-core shielded, 1.5 m

Mechanical

Material
Aluminium alloy
Dimensions
—
Mounting
Threaded, M4
Nominal displacement
≤ 0.03 mm
Weight
—

Safety and compliance

Protection class
IP65
Approvals
CE, RoHS
Calibration
Per unit, certificate supplied with every sample and production order
Material traceability
Batch level, available on request

Drawings and CAD models

Download the STEP model and the dimensioned drawing to check the mounting hole pattern and cable entry against your own assembly. If you need a specific cable length or connector, tell us and we will confirm whether that variant is available or needs to be modified.

Complete the signal chain

A load cell alone gives you millivolts. These are the components our engineers usually pair with MI-50.

ComponentPurposeNote
Sealed junction box, IP67Corner trim adjustment and connector protectionRequired for any multi-cell installation
4–20 mA / RS485 transmitter, 24 VDCConverts to the signal your PLC acceptsMI-50-T1
Shielded 4-core cableSensor to junction box runShielded type — unshielded picks up motor noise
DIN-rail weight indicatorLocal readout at the machineOptional if you read from the PLC

Request the complete bill of materials →

Approvals and certificates

Certificate numbers, covered models and validity dates are listed below. Models not listed are not covered by these approvals.

StandardCertificate no.Covered modelsValid untilDocument
CE—MI-50 series—Request copy
RoHS—MI-50 series—Request copy

Available variants

Other capacities, cable lengths and output options are available on request. MOQ from 1 piece for catalogue variants.

ModelCapacityAccuracyProtectionOutputDatasheet
MI-50-50g50 gC6IP651.0 mV/VPDF
MI-50-100g100 gC6IP651.0 mV/VPDF
MI-50-200g200 gC6IP651.0 mV/VPDF
MI-50-500g500 gC6IP651.0 mV/VPDF
MI-50-1kg1 kgC6IP651.0 mV/VPDF
MI-50-2kg2 kgC6IP651.0 mV/VPDF
MI-50-5kg5 kgC6IP651.0 mV/VPDF

Request a quotation

Send us the application, the load condition and the output signal you need. A named engineer — not an autoresponder — replies within 24 hours with a price indication and lead time.