Find an equivalent to your current load cell

Enter the model you use today. We will return a parameter-by-parameter comparison and flag anything that differs, including whether your drawing needs to change.

Show equivalent
Try:

All available cross-references

Every comparison below is generated from published specification sheets. Where a figure differs, we state the difference rather than rounding it away.

HBM Z6-C3-50KG → SP-50

Equivalent single-point cell. Same M6 threaded mounting and same hole pitch, so no drawing change is required.

ParameterHBM Z6-C3-50KGSP-50Difference
Capacity50 kg50 kgSame
Sensitivity1.0 mV/V1.0 mV/VSame
Accuracy classOIML C3OIML C3Same
Combined error≤ 0.03 %F.S≤ 0.02 %F.SImproved
Creep (30 min)≤ 0.03 %F.S≤ 0.015 %F.SImproved
Temp. effect on zero0.03 %F.S / 10 °C0.02 %F.S / 10 °CImproved
Protection classIP65IP65Same, IP67 optional
MountingM6 threadedM6 threadedSame hole pitch
Cable3 m3 m standardCustom lengths available
No drawing change required — mechanical interface is identicalRequest a free sample →
Zemic L6W-C3-50KG → SP-50

Equivalent single-point cell with the same threaded mounting. Verify the cable length on your BOM before ordering.

ParameterZemic L6W-C3-50KGSP-50Difference
Capacity50 kg50 kgSame
Sensitivity1.0 mV/V1.0 mV/VSame
Accuracy classOIML C3OIML C3Same
Combined error≤ 0.03 %F.S≤ 0.02 %F.SImproved
Protection classIP65IP65Same
MountingM6 threadedM6 threadedCheck thread depth
No drawing change required — mechanical interface is identicalRequest a free sample →
Interface 1022 → SB-200

Shear beam equivalent for platform scales. The mounting style differs — check the baseplate geometry before switching.

ParameterInterface 1022SB-200Difference
Capacity200 kg200 kgSame
Accuracy classOIML C3OIML C3Same
Combined error≤ 0.03 %F.S≤ 0.02 %F.SImproved
Protection classIP65IP67Improved
MountingSingle-ended shearSingle-ended shearVerify rocker pin position
Mounting differs — check your drawing before switchingRequest a free sample →

Technical reference only. The compared model names are the property of their respective manufacturers. This page is an independent parameter comparison and does not imply any affiliation, endorsement or sponsorship. Figures are taken from published specification sheets; confirm against the manufacturer's current datasheet before committing to a design change.

Common questions

Can you supply a drop-in replacement for my current load cell?

For many models, yes. We compare capacity, sensitivity, accuracy class, combined error, creep, temperature effect, protection class, mounting interface and cable length. Where the mechanical interface is identical we say so explicitly, and where it differs we flag it so you know whether your drawing needs to change.

Is this an affiliated product?

No. This comparison is a technical parameter reference only. We are not affiliated with, endorsed by or connected to the manufacturer of any compared model.

Will I get a per-unit calibration certificate with the sample?

Yes. Every sample ships with its individual calibration certificate, so you can verify the actual cell against the datasheet on your own bench rather than taking our figures on trust.