Pre-engineered module with baseplate and rocker assembly, for vessel legs without design work on your side.

Capacities: 50 kg / 100 kg / 250 kg / 500 kg / 1 t / 2 t / 5 tC41.5 mV/VCombined error ≤ 0.015 %F.SCreep ≤ 0.01 %F.SIP68Safe overload 150 % F.S

Full specification

Every figure below is measured under controlled laboratory conditions. Test conditions are stated with the data. A per-unit calibration certificate is supplied with every sample and production order.

Capacity and accuracy

Rated capacity
50 kg / 100 kg / 250 kg / 500 kg / 1 t / 2 t / 5 t
Sensitivity (rated output)
1.5 mV/V
Accuracy class
C4
Combined error
≤ 0.015 %F.S
Non-linearity
≤ 0.015 %F.S
Hysteresis
≤ 0.015 %F.S
Repeatability
≤ 0.01 %F.S
Creep (30 min)
≤ 0.01 %F.S
Zero balance
± 0.05 mV/V
Safe overload
150 % F.S
Ultimate overload
300 % F.S

Temperature

Temperature effect on zero
0.015 %F.S / 10 °C
Temperature effect on output
0.02 %F.S / 10 °C
Compensated temperature range
−10 to +40 °C
Operating temperature range
−20 to +80 °C

Electrical

Recommended excitation
5 VDC
Maximum excitation
15 VDC
Input impedance
405 ± 5 Ω
Output impedance
350 ± 3 Ω
Insulation resistance
≥ 5000 MΩ @ 100 VDC
Recommended cable
4-core shielded, 3 m

Mechanical

Material
Alloy steel
Dimensions
—
Mounting
Complete module, pre-aligned
Nominal displacement
≤ 0.5 mm
Weight
—

Safety and compliance

Protection class
IP68
Approvals
CE, RoHS, OIML R60, ATEX
Calibration
Per unit, certificate supplied with every sample and production order
Material traceability
Batch level, available on request

Drawings and CAD models

Download the STEP model and the dimensioned drawing to check the mounting hole pattern and cable entry against your own assembly. If you need a specific cable length or connector, tell us and we will confirm whether that variant is available or needs to be modified.

Complete the signal chain

A load cell alone gives you millivolts. These are the components our engineers usually pair with WM-500.

ComponentPurposeNote
Sealed junction box, IP67Corner trim adjustment and connector protectionRequired for any multi-cell installation
4–20 mA / RS485 transmitter, 24 VDCConverts to the signal your PLC acceptsWM-500-T1
Shielded 4-core cableSensor to junction box runShielded type — unshielded picks up motor noise
DIN-rail weight indicatorLocal readout at the machineOptional if you read from the PLC

Request the complete bill of materials →

Approvals and certificates

Certificate numbers, covered models and validity dates are listed below. Models not listed are not covered by these approvals.

StandardCertificate no.Covered modelsValid untilDocument
CE—WM-500 series—Request copy
RoHS—WM-500 series—Request copy
OIML R60—WM-500 series—Request copy
ATEX—WM-500 series—Request copy

Available variants

Other capacities, cable lengths and output options are available on request. MOQ from 1 piece for catalogue variants.

ModelCapacityAccuracyProtectionOutputDatasheet
WM-500-50kg50 kgC4IP681.5 mV/VPDF
WM-500-100kg100 kgC4IP681.5 mV/VPDF
WM-500-250kg250 kgC4IP681.5 mV/VPDF
WM-500-500kg500 kgC4IP681.5 mV/VPDF
WM-500-1t1 tC4IP681.5 mV/VPDF
WM-500-2t2 tC4IP681.5 mV/VPDF
WM-500-5t5 tC4IP681.5 mV/VPDF

Request a quotation

Send us the application, the load condition and the output signal you need. A named engineer — not an autoresponder — replies within 24 hours with a price indication and lead time.